REPAIR OF CAR ...MAKE IT YOURSELF!!!
RECOMMENDATIONS FOR CAR REPAIR

Choose section
PASSABLENESS OF THE CAR

ltn141p4-l02 . Now you need to make a term paper topics and do my homework for me,- EssaysReasy.com. . Can you do himself or buying papers online high level. Prix viagra
At unstable work of the engine

At unstable work of the engine or a stop idling causes of defect can be: iphone 4 screen . maja ehitus;DELL STUDIO 1536 REPLACEMENT LAPTOP LCD SCREEN
Too early ignition in ignition cylinders;
Excessive backlash between spark plug electrodes;
Springs a regulator of an advancing of ignition are weakened.
At faults in engine work on any frequency of rotation causes of defect can be:
Damages of a wire to ignition system, easing of fastening of wires or oxidation of their tips;
Pollution, oxidation, burning or displacement of contacts of the breaker;
Decrease in capacity of the condenser or breakage in it;
Deterioration or damage of a contact piece of coal to a cover of the distributor of ignition, easing of a spring of a piece of coal;
Strong the central contact of a rotor of the distributor of ignition;
Too big palpation of the platen of the distributor of the ignition, the raised deterioration of the plug of the platen;
Deterioration of electrodes or spark plugs;
Cracks on a candle insulator.
If the engine does not develop a total power, possible causes of defect can be:
Wrong installation of the moment of ignition;
The big deterioration of the plug of mobile contact of the breaker;
Jamming a regulator of an advancing of ignition, easing of springs.
At a current through interruption contacts - to smooth out contacts and to adjust between them a backlash.
At easing of a clamping spring - to replace contact group. To check up wires and the connections, the damaged wires to replace. To check up and if necessary to replace the switch of ignition or its contact part. If the condenser is punched, to replace it.
At breakage in the primary coil of ignition - to replace the coil.
At breaker contacts - to adjust a backlash between contacts, and at strongly worn out textolite small pillow or the plug the breaker - to replace contact group. If to spark plugs the high voltage for the reasons listed above does not move, it is necessary to check up and restore connections, to clear or replace wires. At deterioration or damage of a contact piece of coal, its lag in a cover of the distributor of ignition - to check up a cover if it is necessary, to replace it.
At current leak through cracks or in a rotor of the distributor of ignition, through a deposit or a moisture on an internal surface of a cover - to clear a cover of a moisture and a deposit, to replace a cover if in it there are cracks.
At breakage or short circuit with "weight" of a secondary winding of the coil of ignition - to replace the ignition coil.
At infringement of an order of joining of wires of a high voltage - to check up and attach wires in an operating procedure of cylinders 1-3-4-2. At a backlash between electrodes of the candles, not corresponding to norm, - it is necessary to clear candles or to adjust a backlash between their electrodes. At damage of spark plugs - to replace candles new. At wrong installation of the moment of ignition - to check up and adjust installation of the moment of ignition.